Max Security Max-G Pro 8 Especificaciones Pagina 21

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 47
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 20
T-Max® Manager/Pro and T-Max® 3A User’s Guide Page 21
Table 2 - Parameter Table
Param # Description Max # Default Notes
1 Address 255 254 Address of timer
2 Beep Mode 1 0 Used for High Pressure beds. The T-Max® 3A will beep 10 seconds half
way through the session. 0=disabled, 1=Enabled.
3 Delay Time 10 0 Delay in minutes stored in the T-Max® 3A.
4 Current Sense 1 0 T-Max® Sentry™ Option. 0=Disabled, 1=Enabled.
5 Session Counts 65535 0 Total session counts for T-Max® 3As.
6 Lamp Hours 65535 0 Bulb hours for each bed.
7 Bed Hours 65535 0 How many hours a bed is on.
8 Manual Session
Counts
65535 0 Counts the # of sessions T-Max® 3A has run as a stand alone timer.
Sessions started from T-Max® Mgr or PC not counted.
9 Clean Room 1 1 0=Clean Room Disabled, 1=Enabled
10* Manual Lockout* 1 0 0=Stand Alone Enabled, 1=Disabled. Prevents the T-Max® 3A from being
an independent timer.
13 Cool Down Mode 10 0 0 = Disabled, 1-10=Enabled. Time delay in minutes allowing bed to cool.
New session cannot start until time expires.
15 Fixed Session Counts 65535 0 Counts number of sessions ran through the T-Max® 3A. This value cannot
be changed. Used as point of reference.
17 Clean Clear 1 0 0 = Press and hold the Set button for 3-4 seconds to clear the clean room.
1 = Press and release the Set button to instantly clear the clean room.
18 Redisplay 2 0 0=After a session ends and the clean room is cleared, the T-Max® 3A will
show a 0. 1=After session ends and the clean room is cleared, the T-Max®
3A will show the last session time entered. 2 = After the session ends and
the clean room is cleared, the max. time will show on the T-Max® 3A.
19 TPI 1 0 Third Party interface mode. Must be set when connecting timer to non-T-
Max® timing system.
20 External Speaker 1 0 Set to a 1 if connecting an external speaker to a T-Max® 3A. Set to 0 if
using speaker on the T-Max® 3A.
21 Pause Mode 1 0 0 = When session is paused, time will continue to count down. 1 = When
session is paused, session time will stop counting down.
22 Auto Bed Shut Off 1 0 For T-Max Intercom Systems Only. 0 = When timer is called bed will stay
on, 1 = When timer is called, bed will stuff off automatically.
* If Manual Lockout is enabled, the T-Max® 3A cannot operate as a stand-alone timer. In the event of a T-Max®
Mgr/Pro failure, this parameter cannot be enabled at the T-Max® 3A
6.3.6 Manager Utilities
Click Manager Utilities with your left mouse button. The window will appear with the
following options:
Download Program from PC to Manager
- Allows you to load the T-Max® Mgr/Pro with
new software
Edit Manager Setup
- Allows you to change T-Max® Mgr/Pro Setting for manual use.
Rescan timers
- Allows you to have the T-Max® Mgr/Pro rescan the timer network
Auto Address
- Allows you to Auto Address the entire salon.
6.3.7 Download Program from PC to Manager
Click Manager Utilities then Download Program from PC to Manager with your left mouse
button.
Vista de pagina 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 46 47

Comentarios a estos manuales

Sin comentarios